Skip to product information
1 of 1

EAST

EAST EAPVESS130K — Diesel-Solar-Storage Hybrid

Regular price Rs 21,140,000
261kWhLFP storage
260kWSolar input
130kWDiesel genset
80%+Less diesel

Cabinet price excludes solar panels, civil works, grid interface and site-specific installation — confirmed on a site survey.

Build a complete system
Authorised EAST Group · Commercial & Industrial

Cut diesel by 80%.
Keep critical loads on.

The EAPVESS130K is a diesel–solar–storage hybrid microgrid in a cabinet. One intelligent controller runs your site on solar and stored energy first — and starts the generator only as a last resort.

⚡Grid ☀Solar ⛽Generator 261 kWh EAPVESS EMS control Your site
Grid · Solar · Generator · Battery — orchestrated in real time, with <20 ms grid/off-grid switching and true black-start.
80%+
less diesel burned vs a generator-only site
261 kWh
liquid-cooled LFP storage, 8,000-cycle life
260 kW
solar PV input across 6 MPPT trackers
<20 ms
grid / off-grid switch, near-seamless
99 %
max conversion efficiency, three-level PCS
520 kW
max output, 4 systems in parallel

The economics, at a glance

Every generator hour avoided is fuel not purchased.

Diesel only
Diesel-only baseline
Diesel + Solar + Storage
up to 75% lower
EAST reports up to 75% lower comprehensive energy cost versus a diesel-only baseline. Your site-specific energy cost and diesel savings are calculated from your generator efficiency, diesel price, solar yield, load profile and operating schedule — modelled in your proposal.
The EAST EAPVESS130K is an integrated diesel–PV–storage hybrid power system for industrial and commercial sites: it intelligently orchestrates four power sources — the grid, on-site solar (up to 260 kW PV input), a diesel generator (up to 130 kW) and 261 kWh of LFP battery storage — in one liquid-cooled outdoor cabinet system with a built-in EMS controller. It lets a site run primarily on solar and stored energy, using the generator only as a last-resort backup, cutting diesel consumption by more than 80%.Best for: hotels, factories, telecom sites, islands, mining and remote operations that today rely on a diesel generator and want to slash fuel costs, manage peak demand, and keep uninterrupted power through outages.
What's included in this price

Rs 21,140,000 gets you

The complete two-cabinet system — the equipment cabinet (bi-directional PCS, six-MPPT solar input, EMS microgrid controller, and the grid- and generator-communication/control interface hardware) and the battery cabinet (261 kWh LFP with liquid cooling, aerosol fire suppression and high-voltage box) — factory-integrated and delivered as one outdoor system. Not included: the solar panels (the cabinet provides the 260 kW PV input; panels are quoted separately), the diesel generator (the system connects to your existing or a new genset), and project engineering — utility/grid approval, protection study and settings, external ATS/switchgear, cabling and containment, civil foundations, and generator/ATS integration and commissioning — which are confirmed on a commercial site survey because they vary so much by site.

Indicative equipment price for the base configuration — one equipment cabinet and one 261 kWh battery cabinet. VAT, price validity and any exchange-rate adjustment, plus the solar array, switchgear, cabling, civil works, delivery and commissioning, are confirmed on your engineering quotation. Product images may illustrate a larger multi-cluster configuration.

How it works

One controller, four power sources.

Solar first

Up to 260 kW of PV runs the site and charges the battery through the day across six MPPT trackers — the site's lowest marginal-cost energy source.

Battery next

261 kWh of LFP storage carries the load into the evening and through peak-tariff windows. Expandable to a full 8-hour backup system.

Grid when useful

In grid-connected mode the system charges off-peak and discharges at peak for time-of-use arbitrage, with power factor ≥0.99 and THDi ≤3%.

Generator only as last resort

The EMS starts the diesel generator only when solar, battery and grid can't cover the load — reducing generator runtime, fuel and maintenance by more than 80%.

Key benefits

Why sites choose the EAPVESS130K.

Cut diesel by 80%+

Solar and storage do the heavy lifting; the generator becomes a rarely-used backup. EAST reports comprehensive energy cost reduced by up to 75% versus a diesel-only site.

Uninterrupted power

Millisecond-level switching (<20 ms grid/off-grid) and true black-start capability keep designated critical loads running through outages, subject to battery state of charge and approved site design. Highly sensitive equipment may still warrant a dedicated UPS.

Peak-shaving & arbitrage

Shift load out of expensive peak windows and, on grid, arbitrage the peak/off-peak price difference. Outcomes depend on tariff, load profile and operation.

Liquid-cooled, long life

Cold-plate liquid cooling holds cell-to-cell temperature difference under 3 °C, supporting >8,000 cycles and cutting auxiliary power by ~30% versus air-cooled cabinets.

Safe by design

Open aerosol fire suppression across the full cabinet, real-time safety monitoring with early warning, 3-level short-circuit and 4-level active protection, and per-pack aerogel insulation.

Built for harsh sites

C4 corrosion resistance (C5 optional), IP54 cabinet with IP65 distribution / IP66 PCS / IP67 battery packs — engineered for islands, cement plants and mining areas.

The economic case

The commercial case for diesel displacement.

A commercial site running a diesel generator pays for every litre it burns. By putting solar and 261 kWh of storage in front of the generator and letting an EMS decide when — if ever — the genset runs, the EAPVESS130K targets a diesel-consumption reduction of more than 80% and a comprehensive energy-cost reduction of up to 75% against a diesel-only baseline (EAST figures). Fewer generator hours also means lower maintenance, less noise, and roughly 80% lower carbon emissions. In grid-connected mode, off-peak charging and peak discharging add a further arbitrage return. Actual savings and payback depend on your tariff, fuel price, load profile, solar sizing and how the system is operated — we model these for your specific site in the proposal.

Technical specifications

Full specifications

Battery & storage
System nominal capacity 261 kWh
Cell chemistry LFP 3.2 V 314 Ah
Rated voltage 832 Vdc
Battery cluster range 728–949 Vdc, 1P260S
Max expandable 4 clusters (up to an 8-hour system)
Cooling Liquid cooling, cold-plate type
Cycle life ≥ 8,000 cycles @ 25 °C
Charge/discharge rate 0.5P

System role

A diesel–PV–storage hybrid microgrid: orchestrates grid, solar, generator and battery via an on-board EMS for maximum solar self-consumption, peak-shaving, arbitrage and backup. Sized to your load, tariff and fuel cost.

Expansion

Horizontal: up to 4 battery strings → 8-hour backup system. Vertical: up to 4 systems in parallel on the AC side → 520 kW output.

Expansion note: systems with 3 or 4 battery cabinets require the EAST ESMU energy-storage management unit and DC switchgear — included in the relevant quotation.

Installation

Two-cabinet outdoor siting on prepared bases, three-phase connection, generator/ATS integration, grid-interface engineering and commissioning by MyEnergy Solutions, per project design.

Specifications

EAPVESS130K 261kWh Diesel–PV–Storage Hybrid System — full datasheet

Battery parameters
Battery type LFP 3.2 V 314 Ah
System nominal capacity 261 kWh
Rated voltage 832 Vdc
Battery cluster range 728–949 Vdc
Assembly method 1P260S
Max expandable quantity 4 clusters (3–4 cabinets require ESMU + DC switchgear)
Cooling mode Liquid cooling (cold-plate type)
Photovoltaic (solar) input
Max input power 260 kW
Max input voltage 950 Vdc
Rated input voltage 810 Vdc
Start-up voltage 220 Vdc
Min operating voltage 200 Vdc
MPPT voltage range 200–950 Vdc
Max MPPT input current 52 A (55 A instantaneous)
Number of MPPT 6 (max 3 strings per MPPT)
Grid parameters
Rated power 260 kW / 130 kW
Voltage range 380/400 Vac (−20% to +20%), 3L/N/PE
Rated input / output current 394 A / 376.8 A · 197 A / 188.4 A
Rated frequency 50 Hz ± 2.5
Total harmonic distortion (THDi) ≤ 3%
Power factor ≥ 0.99
Diesel generator & load
Generator rated power 130 kW
Generator voltage 380/400 Vac (−20% to +20%), 3L/N/PE
Generator rated current 197 A / 188.4 A
Load rated power 130 kW
Load rated AC current 197.5 A
Load frequency 50 Hz ± 2.5 / 60 Hz ± 5
System parameters
AC wiring method Three-phase four-wire
Grid / off-grid switching time < 20 ms
Power response time ≤ 200 ms
Max conversion efficiency 99%
European / MPPT efficiency 98.2% / 99.9%
System functions Active & reactive power dispatch, grid voltage support, three-phase unbalance compensation, harmonic suppression, black start, peak-shaving & valley-filling
Communication LAN, RS485, TCP/IP, IEC61850
Remote monitoring EMS + mobile app
Safety, environment & physical
Fire protection Full-cabinet open aerosol + active monitoring + water fire protection (pack-level perfluorohexanone optional)
Protection 3-level short-circuit, 4-level active protection, emergency stop, door lock
IP rating IP54 cabinet · IP65 distribution · IP66 PCS · IP67 battery pack
Corrosion resistance C4 standard (C5 optional)
Operating temperature −20 to 60 °C (derating above 45 °C)
Relative humidity / altitude < 95% RH non-condensation · < 4000 m (derating above 2000 m)
Noise level < 75 dB
Battery cabinet 1000 × 1350 × 2250 mm · ≤ 2200 kg
Equipment cabinet 700 × 1350 × 2250 mm · ≤ 1000 kg
Combined weight ≤ 3200 kg
Warranty 10-year warranty on eligible EAST ESS packages. Final terms and covered components confirmed in your official quotation.
Figures from the official EAST EAPVESS130K datasheet. Final configuration, generator integration, battery pairing and warranty are confirmed on your quotation. MyEnergy Solutions is the authorised EAST Group distributor for Sri Lanka and the Maldives.
Where it's used

Proven applications.

PV-storage-charging hubs

Solar, storage and EV charging integrated at fuel stations and fleet depots.

Factory & hotel peak-shaving

User-side storage that shaves demand charges and shifts load off the peak tariff.

Diesel–PV–storage microgrids

Islanded and expressway sites where the grid is weak, absent or expensive.

Remote & harsh sites

Islands, mining and cement plants that today run on continuous diesel.

Warranty & documentation

Up to 10-year warranty

10-year warranty on eligible EAST ESS packages. Final warranty terms and covered components will be confirmed in your official quotation. Specifications are taken from the official EAST datasheet. MyEnergy Solutions is the authorised EAST Group distributor for Sri Lanka and the Maldives.

Frequently asked questions

Frequently asked

How does it cut my diesel bill?
The on-board EMS runs your site on solar and stored energy first, then grid, and only starts the diesel generator as a last resort. Because the generator runs far less, EAST reports diesel consumption down more than 80% and comprehensive energy cost down up to 75% versus a diesel-only site. We model the exact figures for your fuel price, tariff and load in the proposal.
Do I keep my existing generator?
Yes. The system is designed to integrate a diesel generator (up to 130 kW) as backup — your existing genset or a new one. It orchestrates the generator alongside grid, solar and battery rather than replacing it.
Will it keep critical loads running in a blackout?
It maintains designated critical loads through outages, subject to battery state of charge, system capacity and approved site design. It has true black-start capability and switches grid/off-grid in under 20 ms; highly sensitive equipment may still warrant a dedicated UPS.
Can it be expanded?
Yes. Battery capacity expands to 4 clusters for an 8-hour system, and up to 4 systems run in parallel on the AC side for 520 kW of output. Configurations with 3 or 4 battery cabinets require the EAST ESMU energy-storage management unit and DC switchgear, which are included in the relevant quotation.
Is it suitable for outdoor and harsh environments?
Yes. It's a self-contained outdoor cabinet system with liquid cooling, aerosol fire suppression, C4 corrosion resistance (C5 optional) and IP54–IP67 protection across components — suitable for islands, mining and cement plants.
How is it sized and priced?
Through a commercial site survey covering your solar potential, load profile, tariff, fuel cost and backup requirements. The listed price is the cabinet system; panels, generator integration and site works are confirmed on your quotation.

Savings: actual diesel, energy-cost and payback outcomes depend on your load profile, tariff, fuel price, battery and solar sizing, usage timing and how the system is operated. Figures cited are EAST reference figures, not a guarantee for your site.

Grid export: not required for savings. This system is designed for self-consumption, backup and diesel displacement; any site-specific connection, protection or utility requirements are confirmed during engineering review.

Specifications and warranty: specifications per the official EAST datasheet; warranty coverage of up to 10 years, confirmed on quotation and local project scope.